Sample Questions

Question 1
Central tube also known as which term?
Single loose tube
Core tube
Unitube
Central tube
Explanation:
In loose-tube fiber optic cables, the fibers are housed inside tubes that run along the length of the cable, with one tube located at the very center. That central channel is commonly called the core tube because it forms the core housing for the fiber bundles, literally the tube around which the cable’s fiber path is organized. The other terms describe different concepts: a single loose tube refers to a design with just one tube containing all fibers, which is a different configuration; unitube isn’t a standard designation in this context. So the central tube is best known as the core tube.
Question 2
What is the correct description of a license in real property terms?
A long-term ownership right
A transferable fee interest
Temporary permission to use land
A mortgage lien
Explanation:
A license describes a temporary permission to use land without granting ownership or exclusive possession. It is usually revocable and personal to the licensee, meaning the owner can withdraw the permission and it ends once the stated purpose is fulfilled. It does not create an estate in land and, unless explicitly stated, does not run with the land or transfer with ownership. The other options describe ownership interests or a security interest (like a mortgage lien), not just permission to use.
Question 3
Gel filled RUS cable corresponds to which standard code?
PE89
PE86
PE39
PE7
Explanation:
In this case, the standard code used for identifying cables is the RUS designation system, where a prefix like PE is followed by a two-digit code that denotes the specific construction and filling of the cable. Gel-filled RUS cables are classified under the PE86 code. That suffix encodes the gel-filled moisture-protection construction defined by RUS for that type of cable, ensuring it’s the correct match for gel-filled, moisture-resistant designs used in underground or duct environments. The other codes correspond to different cable constructions or filling methods and don’t match the gel-filled category, so they wouldn’t be correct for a gel-filled RUS cable.
Question 4
The vertical down lead (VDL) of the MGN is an acceptable ground.
False
True
Not Acceptable Ground
Unknown
Explanation:
The main idea here is that a reliable ground comes from a continuous, low-impedance path to earth provided by the bonding of the Main Grounding Network to the grounding electrode system. The vertical down lead is the conductor that takes the MGN down to the earth, terminating at a grounding electrode. When this lead is properly sized, securely connected, and bonded to both the MGN and the electrode, it delivers the required low-impedance path to earth. That makes it an acceptable ground for the MGN. If the lead isn’t bonded to an electrode or is undersized or poorly connected, it wouldn’t be an acceptable ground, but with correct installation it is.
Question 5
GACAN limits use of how many different gauges?
one
three
four
two
Explanation:
Limiting the number of conductor gauges to two keeps the electrical characteristics of a run predictable and manageable. When only two sizes are used, resistance, inductance, and capacitance stay within a narrow range, which makes terminations, splicing, and testing more straightforward and reliable. Introducing a third or fourth gauge would introduce more variability in impedance and other properties, making it harder to certify performance and maintain consistency across the installation. That balance—enough flexibility to accommodate practical needs (such as different gauges for different functions) while avoiding excessive complexity—leads to allowing two gauges. Using only one gauge would be too restrictive for common installations, and three or four gauges would complicate design and testing without real benefit.

Ready to test your knowledge?

Buy Now to Access

Additional Information

BICSI OSP Design Practice Test

This practice set contains 10 questions from the matching question bank and focuses on central, lead, topology, bicsi, and design. Work through each question carefully, review the provided solutions, and revisit topics that need more study before your next attempt.

This is an independent study resource intended for practice and review; it is not an official examination or an endorsement by any organization named in the title.

Frequently Asked Questions

This quiz contains a total of 10 practice questions carefully selected to test your knowledge on this subject.
Yes, you will have exactly 0 minutes to complete the exam. A countdown timer will be visible once you start.
Yes, you can retake this practice test as many times as you need. The questions and options may be randomized on subsequent attempts to ensure comprehensive learning.

Reviews

5.0

Based on 0 reviews

Leave a Review

No reviews yet. Be the first to review!